IEC60335 is the discharge safety standard for all appliances. To protect the user from an electrical hazard, it requires the voltage across the input X capacitor to discharge to less than 34 V within ...
There are many applications which require pulse power. The needed burst of energy is derived by rapidly discharging a previously charged capacitor. As the energy stored in a capacitor is equal to ...
The residual voltage of a capacitor, rated not over 600V, shall be reduced to 50V or less within _____ after the capacitor is disconnected from the source of supply. Article 460 covers the ...
Power Integrations is aiming at larger home appliances needing to meet IEC60335 with an X-capacitor discharger that can empty 6µF in under a second. X-capacitors are part of the EMC input filter of ...
Power Integrations successfully meet the IEC 62368 standard on its CAPZero™ family of innovative, two-terminal, automatic X-capacitor discharge ICs. The IEC 62368 is the new over-arching safety ...
UK based ARCOL Resistors has introduced its RW Discharge Resistor. This wire-wound resistor is designed for quick and easy mounting on to capacitors and is typically used as a discharge or balancing ...
DC testing of solid dielectric cable is largely ineffective, highly discouraged, and discontinued by most. The preferred method is to use AC voltage to test cables, and for long cable runs, a Very Low ...
Many power supplies use hold-up capacitors to keep enough energy at the full-wave or bridge rectifier output to supply a load when the rectified voltage drops and rises again at the next half-cycle of ...